- AC Voltage: 15V/100V/300V/750V, ±(1.2%+5)
- AC Current: 40A/100A/400A/1000A, ±(2%+5)
- True Power: 0.60kW-750kW, ±(3%+5)
- Apparent Power: 0.60kVA-750kVA ±(3%+5)
- Reactive Power: 0.60kVAr-750kVAr ±(4%+5)of 15V/1000A else±(4%+5)
- Power Factor: 0.3-1 ±(2%+20)
- Phase Angle: 0° -90° ±1
- Frequency: 20Hz-200Hz ±(0.5%+5)
- Energy: 1-9999kWh ±(3%+2)
- Dimensions : 295(H) x 100(W) x 46(D)mm
Warranty:
1 year
- Analysis for single phase and balanced 3 phase system
- True RMS Value (Voltage Current)
- Large LCD Display with Backlight
- USB interface
- Min/Max measurement
- True Power/Apparent power/ power factor measurement
- Data Hold/ Auto ranging / Overflow indication/ Auto power Off
Clamps measure current. Probes measure voltage. Having a hinged jaw integrated into an electrical meter allows technicians to clamp the jaws around a wire, cable or other conductor at any point in an electrical system, then measure current in that circuit without disconnecting/deenergizing it.