Working temperature: 0°C to 50℃, 70%R.H.
Storage temperature:-20℃ to +70℃,80%R.H.
Battery type: 9V DC, NEDA 1604,6F22,006P
Effective measuring range:
10mV/A: 1A to 40A, DC or rms AC
1mV/A: 1A to 500A, rms AC
1A to 800A, DC
DC current: ±(1.5%+0.5A) 1A ~40ADC current: 1mV/A
AC current (OHz to 500Hz): 10mV/A±(2%+0.5A)1A ~40A
AC current (0Hz to 5KHz): 1mV/A±(2%+0.5A)1A~ 500A
Load resistance: 10KQ typical
DC current: 10mV/A
±(1.5%+0.5A) 1A ~40ADC current: 1mV/A
±(1.5%+0.5 A)1A to 800 A.
AC current (OHz to 500Hz): 10mV/A±(2%+0.5A)1A ~40A
AC current (0Hz to 5KHz): 1mV/A±(2%+0.5A)1A~ 500A
Load resistance: 10KQ typical
Temperature coefficient: 0.1×(specified accuracy) temperature coefficient. (OR℃ to 18℃, 28°C to 50C)
Warranty:
As per Brand policy